Check air flow across heat sink, check inverter tight to heatsink use thermal paste. Set ALL indoor units to cooling or ALL to heating to clear. If you see fault code CH07 only type 7 in your text message CH60 Outdoor unit PCB EEPROM failure, try removing EEPROM and refitting if removable (possible contact fault), otherwise replace Get a Professional Answer Via email, text message, or notification as you wait on our site.Ask follow up questions if you need to. 100% Satisfaction Guarantee Rate the answer you receive. check over here

Disconnect from PCB measure resistance 237 kOhm at 20C and 168 kOhm at 30C. If OK replace PCB, if not replace sensor CH45 Outdoor unit coil sensor fault. York Error Code York Minisplits Temperature Sensor Resistance Readings Temperature = 0C K Ohms = 35K Temperature = 10C K Ohms = 20K... C4 RAC Product = Heat Sink Sensor Error, Open/Short Cct or over 95C.

Lg Inverter Air Conditioner Error Codes

Firstly check the compressor is correctly connected. if not replace sensor. If OK, mismatching of controllers, or defective CNU 244 Central controller data receiving time out. Reply dhanraj narayan says: July 12, 2016 at 8:13 am very useful information nice Reply amar yadav says: August 10, 2016 at 7:02 am oll air co error cord plz mail

If OK replace PCB, if not replace sensor CH46 Outdoor unit suction sensor fault. no heating or cooling. If OK replace either main or fan PCB 109 Sub 1 excessive rise of high pressure. Lg Air Conditioner Ch 10 Error If OK, replace either main or fan PCB 106 Outdoor unit fan motor high current.

CH61 Condenser coil over 65C. Check motor for mechanical and/or electrical failure, if okay replace pcb. 100 Excessive discharge temperature rise 105C Sub condenser 1 standard compressor. Check your wiring . http://www.manualslib.com/manual/92718/Lg-General-Wall-Mounted-Inverter-Type.html?page=66 CH 5 on these units indicates a communications error between the indoor and outdoor units.

Check output from main PCB, check contactor, and check wiring connections. Lg Multi V Error Codes Check pressures, check for non condensables, check heat exchanger coil is free from debris 171 Sub 3 check power supply voltage to the outdoor unit is correct (1ph 220 Vac 10% Add × Loading... Check system pressures for non-condesables CH62 Inverter over 85C.

Lg Air Conditioner Error Code Ch 05

LowOutdoor Status = OffError Code = 65Contents = Heat Sink Sensor (Open/Short)LED01G = 6 times(Red) LED02G = 5 times(Green)Case Of Error = Open / Short circuitOutdoor Status = OffError Code = http://www.fixya.com/tags/lg_ch_62/air_conditioners/lg Multi V: 1 Vdc = 4 bar up to 5 Vdc = 32 bar 43 High pressure sensor fault. Lg Inverter Air Conditioner Error Codes If OK replace PCB, if not replace sensor CH48 Split/Multi Split = Outdoor unit discharge and air sensor both unplugged. Lg Air Conditioner Error Codes Pdf How to fix the CH6 error?

Multi V = High pressure trip. 25 Check power supply voltage to the outdoor unit is correct (1ph ?220 Vac 10% or 3ph ?380 Vac 10%). http://jvmwriter.org/error-code/lg-error-code-dh.html Contact: Call: +44(0)845 567 7080 E-mail: [email protected] Fault Codes: Keyword Response 00 Text the 1, 2 or 3 digit fault code number only. Tip: The max point reward for answering a question is 15. 0 characters Video Photos Link Replacement Parts Add Upload Upload × × Draw a box over the problem!! RAC Indoor unit BLDC Fan problem. Lg Mini Split Error Codes

The compressor will try to start 3 times then the fault will recur. Matthew and other HVAC Specialists are ready to help you Ask your own question now Customer: replied6 If OK replace PCB, if not replace sensor 47 Compressor discharge sensor fault. Multi V = Indoor unit EEPROM error - Replace the indoor unit PCB, and then make sure to do Auto addressing and input the address of central control. 10 RAC http://jvmwriter.org/error-code/lg-error-code-53.html Multi V: 1 Vdc = 4 bar up to 5 Vdc = 32 bar 159 Sub 3 outdoor unit air sensor fault.

Disconnect from PCB and measure resistance. 10 kOhm at 10C and 4 kOhm at 30C 128 Sub 2 high pressure sensor fault. Lg Inverter Air Conditioner Troubleshooting Temp. If you see fault code CH07 only type 7 in your text message CH39 no such fault code Text 1, 2 or 3 digit fault code number only.

Multi V - also check Sub outdoor unit dipswitch settings CH52 Communication error between inverter PCB and main outdoor unit PCB.

Question about Art Cool LA121CNP wall/window Air Conditioner 1 Answer LG error CH 64 LG error CH 64 Hi, My Lg art cool display de error CH 64, anyone know the Multi V: 1 Vdc = 8 bar up to 2.5 Vdc = 37 bar CH44 Outdoor unit air sensor fault. Check comms wiring is correct, and check initialisation has been carried out correctly CH12 no such fault code Text 1, 2 or 3 digit fault code number only. Lg Neo Plasma Error Codes Recently it stopped working.

If OK, check fuses, if fuses are OK replace outdoor main PCB CH26 Inverter compressor seized. Compressor (Open/Short)Open / Short CircuitOff 444 times4 timesAir Sensor (Open/ShortOpen / Short circuitOff 454 times5 timesCond. If you see fault code CH07 only type 7 in your text message 56 no such fault code Text 1, 2 or 3 digit fault code number only. http://jvmwriter.org/error-code/lg-error-code-oe.html Disconnect sensor from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C if not replace sensor 02 Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or

Lookup LG parts on the internet or ring them for your nearest Agent or parts stockist. PDF Manual Http://www.lgservice.com/jsp/common/do... If OK compressor faulty 204 Comms Error between Outdoor Unit and HR Box No1. 1. Unfortunately, it will probably also fuel global warming, a new study finds.air conditioninair conditionerac air conditioningfurnacehvac Christian dela cruz on May 22, 2013 at 10:37 AM said...

This is caused by the Indoor fan being locked. LG LS-L1210CL Mini... Check pressures, and check service valves open CH36 no such fault code Text 1, 2 or 3 digit fault code number only. Check Outdoor fan motor is plugged in, Electrically & Mechanically sound, if not replace motor, otherwise replace PCB.

Check compressor windings all equal 1 to 4 Ohms . Check all 3 phases are present and correct.