Home > Error Code > Lg Art Cool Air Conditioner Error Codes

Lg Art Cool Air Conditioner Error Codes

Contents

Pipe Sensor Temp. nvozella Jan 06, 2009 Model No. If OK replace PCB, if not replace sensor 137 Sub 2 outdoor unit liquid pipe sensor fault. Contributor 6 Answers Re: ERROR CODE ON AIRCONDITIONER LG ART COOL INVERTER... check over here

The malfunction indicator of indoor (see the operating LED of the INDOOR) Error CodeThe cause of malfunctionMalfunction indicatorThe operating state 1Indoor TH. Check fans rotate freely, and are connected correctly 107 Outdoor unit low voltage to fan PCB. Disconnect from PCB and measure resistance. 10 kOhm at 10C and 4 kOhm at 30C. I.e.

Lg Inverter Air Conditioner Error Codes

Contributor 1 Answer Re: ERROR CODE ON AIRCONDITIONER LG ART COOL INVERTER... If you see fault code CH07 only type 7 in your text message CH57 Comms error between outdoor main PCB and inverter PCB. He could not fix it as the full control panel needs to be replaced... If over 105C, check refrigerant charge 33 Excessive rise of standard compressor discharge temperature.

If correct voltage appears at all three phases, swap any two to cure the fault 111 Communication error between Main and Sub outdoor units. for another 5 mins..  Same symptom as others here - c6 error code after aroudn 5 mins of running. We can ship Lg air conditioning spare and parts including wall, cassette, floor, ducted and multi air conditioning units parts. Lg Inverter Air Conditioner Troubleshooting Multi V - also check Sub outdoor unit dipswitch settings 52 Communication error between inverter PCB and main outdoor unit PCB.

AC Error Code Error Codes of All Air Conditioning Brands. Lg Air Conditioner Error Codes Pdf If you see fault code CH07 only type 7 in your text message CH18 no such fault code Text 1, 2 or 3 digit fault code number only. Answer questions, earn points and help others Answer questions Manuals & User Guides PDF Manual Da718f73-ef00-4a71-969c-6c7626c20088-1... Switching off at the Fuse Box clears the error.Steps taken after that.1.

Out of rangeor defective thermistor can shut the operation of the unit.- If your indoor and outdoor is clean start the unit in cool mode and monitor the outdoor pipes. Lg Neo Plasma Error Codes High (Cons. Wrong setting of the HR unit Rotary switch and Dip switch 3. Reply Jones says: June 21, 2016 at 9:43 pm What might be the possible cause of the out door condensercoil overheating.

Lg Air Conditioner Error Codes Pdf

If you live in Melbourne, call WAM Electrical in Box Hill... is open or short• Heat-sink TH. Lg Inverter Air Conditioner Error Codes Disconnect from PCB and measure resistance. 10 kOhm at 10C and 4 kOhm at 30C.if not replace sensor 133 Sub 2 compressor 1 discharge sensor fault. Lg Mini Split Error Codes Panasonic mini split air conditioner css9nkua error code h99 what does it mean ...ERROR CODE ON AIRCONDITIONER LG ART COOL INVERTER MODEL .

If OK, check fuses, if fuses are OK replace outdoor main PCB 26 Inverter compressor seized. http://jvmwriter.org/error-code/lg-art-cool-c6-error-code.html Check compressor windings all equal resistance 1 to 4 Ohms, check to earth 50 MOhm minimum, check run current and inverter outputs 41 Inverter compressor discharge sensor fault. Disconnect from PCB measure resistance. 237 kOhm at 20C and 168 kOhm at 30C. Whatever the reason, it is very important to check the error code, because it is a clue to troubleshooting the appliance. Lg Air Conditioner Error Code Ch 05

Have tried resetting, BUT nothing. Filter is clean, and after error requires a mains turn-off before it will work again... Check dc voltage of capacitors 300 Vdc for 1Ph and 600 Vdc for 3Ph. http://jvmwriter.org/error-code/lg-art-cool-error-code-ch-07.html is short or open• Indoor TH. (sensor) is short or open • Indoor TH. (sensor) is not connected to the indoor pcb assembly • Damage or defect on the sensing circuit

Check drain pan is empty, check pump is working OK. Lg Thermostat Error Codes Unfortunately, it will probably also fuel global warming, a new study finds.air conditioninair conditionerac air conditioningfurnacehvac Christian dela cruz on May 22, 2013 at 10:37 AM said... adamtaylor Nov 30, 2008 keep getting error code c6 on the inside unit, we have tried cleaning the filter and resetting the power which helps for about 5 mins then it

The second powers up, vents open, but the fan does not run.

York Error Code York Minisplits Temperature Sensor Resistance Readings Temperature = 0C K Ohms = 35K Temperature = 10C K Ohms = 20K... Either defective CNU or Central controller initialisation failure 250 Central controller data receiving error. Set to Sg for 1 unit, or Gr for group then reset power 3 Remote controller comms error. Lg Multi V Error Codes I think half the problem here is that the error is too generic & must cover alot of different possible faults/issues.

Contributor 4 Answers Re: ERROR CODE ON AIRCONDITIONER LG ART COOL INVERTER... If OK either inverter or main PCB defective CH53 Comms error indoor to outdoor unit. check fuses, if fuses OK replace outdoor main PCB 149 Sub 2 check power supply voltage to the outdoor unit is correct (1ph 220 Vac 10% or 3ph 380 Vac 10%). http://jvmwriter.org/error-code/lg-art-cool-error-code-ch-46.html if not replace sensor 162 Sub 3 compressor 1 discharge sensor fault.

Click the Infrared unit switches the unit off. 2. Check air flow across heat sink, check inverter tight to heatsink use thermal paste. Check all comms wiring, including between controller and CNU, and IP addresses. Contributor 1 Answer Re: ERROR CODE ON AIRCONDITIONER LG ART COOL INVERTER...

If OK replace PCB, if not replace sensor CH47 Compressor discharge sensor fault. There's seems to be a cooler draught around the room associated with the heat - somehow? Share on Facebook Share on Twitter Share on Google+ Share on Pinterest Share by Email × Question about Air Conditioners 10 Answers ERROR CODE ON AIRCONDITIONER LG ART COOL INVERTER MODEL Check coil and filters are clean and free from debris, and airflow is OK.

Check comms wiring and power to all outdoor units 157 Sub 3 high pressure sensor fault. http://www.lg.com/us/appliances/air-conditioners/LG-art-cool-LA121CNP.jsp?subCatId=1000001014 Jun 21, 2010 | LG Art Cool LA121CNP wall/window Air... 1 Answer Hello have a inverter LG Airconditioner and it keeps turning itself off and showing the letters C6? If OK, replace fan PCB 108 Communication error between outdoor main PCB, and fan PCB. I have tried to get assistance on the LG service site, but nothing on error codes.

Check drain pan is empty, check pump is working OK. How to fix lg with code CH05 - Fixya www.fixya.com/support/t12722126-fix_lg_code_ch05May 8, 2012 - Question about LG Air Conditioners. 2 Answers ... is short or open• Outdoor TH. (sensor) is short or open • Outdoor TH. (sensor) is not connected to the outdoor pcb assembly • Damage or defect on the sensing circuit Ours started playing up on January 24th and despite phone calls to the reseller and LG at least once a week, we've been told today that the part that was to

Text 45 for diagnostics 49 Check power supply voltage to the outdoor unit is correct (1ph ?220 Vac 10% or 3ph ?380 Vac 10%).