I've seen this error several times in trivial scenarios and I can't understand why it should be the user's problem to avoid the "resource busy" error when a timeout is specified. Check the XML description. 400563 QERR_NO_MORE_ETHERCAT_PACKETS The EtherCAT master puts a limit on the number of packets which may be queued for transmission. This privilege is only enabled by default for administrators, services and the local system account. These folders can be found at the location found in[National Instruments]\Shared\MIerrorsas shown below. this contact form

Note that if you set DAQmxRead.RelativeTo = Most Recent Sample, and Offset = 0, it will actually wait until the next sample arrives (Traditional NI-DAQ did this too). The board-specific HIL driver is likely not compatible with the operating system specific kernel-level driver for the board. Either the Data node or the DataLength node is required because they provide the data for the command. 400597 QERR_MISSING_ETHERCAT_VALIDATE_DATA Missing Data node within the Validate section of an InitCmd in NOTE: You do not need to reinstall DAQmx.5.Self-test and Reset the device in MAX—if the board is still not functioning it will throw the error here.6.If possible, try the device in

Ni Daqmx Error

If you find a different way, it would be great to hear about it, but I gave up. The kernel-level driver is the driver that gets installed when the operating system detects the hardware. The Addr node identifies the logical address and is a required field when a LRD, LWR or LRW command is used. 400593 QERR_MISSING_ETHERCAT_ADDRESS_PAGE Missing Adp node within an InitCmd in EtherCAT The Config node identifies the EtherCAT configuration and is required. 400612 QERR_MISSING_ETHERCAT_SLAVE Missing Slave node within the EtherCAT XML configuration file.

The numbers you have posted are not DAQmx error codes that I have ever seen before. Use < to put a '<' in an attribute value. 400476 QERR_INVALID_XML_ENTITY_REFERENCE Invalid XML entity reference. The board-specific HIL driver is likely not compatible with the operating system specific kernel-level driver for the board. Labview Visa Error Codes It may be necessary to uncheck the two "Set clock parameters..." options in the HIL Initialize block. 400703 QERR_HIL_SET_CLOCK_MODE_NOT_SUPPORTED The hil_set_clock_mode function is not supported by this particular card. 400704 QERR_HIL_SET_DIGITAL_DIRECTIONS_NOT_SUPPORTED

Try one of the more specific functions or blocks. 400723 QERR_HIL_TASK_CREATE_READER_WRITER_NOT_SUPPORTED The hil_task_create_reader_writer function and HIL Read Write Timebase block are not supported by this particular card. What sort of hardware are you using? The Name node identifies the name of the slave and is required. 400604 QERR_MISSING_ETHERCAT_CYCLIC_STATE Missing State node within a cyclic Cmd node in EtherCAT XML configuration file. you could check here The Transition nodes indicate the state transitions forward to the command should be executed and is a required field. 400599 QERR_MISSING_ETHERCAT_RETRIES Missing Retries node within an InitCmd in EtherCAT XML configuration

The InitCmds section includes all the EtherCAT initialization commands for the slave and is required. 400602 QERR_MISSING_ETHERCAT_SLAVE_COMMAND Missing InitCmd node within a Slave in EtherCAT XML configuration file. Labview Error 1073807339 I'd think that your best bet is to use van18's semaphore suggestion. It may be out of an acceptable range. 400270 QERR_SOCKET_NOT_REUSABLE The socket address could not be made reusable. 400271 QERR_CANNOT_BIND_SOCKET It was not possible to bind the socket to the given So is there a document somewhere, or a web page, or something I can access where I can find out the meaining of these error codes? 1 Kudo Message 1 of

Ni Error Code

A DPC object cannot be used after it has been closed. 400307 QERR_INVALID_METHOD The method code received is not valid. http://digital.ni.com/public.nsf/allkb/95328C2FAF9DA99A862576E200785C11 All rights reserved. | Cart|Help KnowledgeBase Request Supportfrom an engineer NIHome > Support > KnowledgeBase EnglishChinese(China)SpanishKoreanChinese(Taiwan) 7 ratings: 2.85 out of 5   What do Ni Daqmx Error It's easy! Labview Visa Error -1073807339 This will occur at start up and if the calibration cycle fails then the device will be inoperable until the system is restarted and the device boots correctly.

Solution: Because error codes are continually added to National Instruments software a comprehensive list of error code ranges is not maintained, with the exception of LabVIEW. http://jvmwriter.org/error-code/labview-error-code-63040.html If the board cannot communicate with the FPGA it will not function.Both of these error codes indicate fairly general problems that may have a number of causes in both hardware and/or I was able to find an NI knowledge base entry, http://digital.ni.com/public.nsf/allkb/04BEDD9E9E91ED3486256D180048116D' target="_blank">Causes of NI-DAQmx Error 50103 "The Specified Resource is Reserved", which addresses this issue. DAQmxGetErrorString doesnt work. Labview Error 200279

It is a code unit that is only valid in the middle of a UTF-8 character. 400493 QERR_TRUNCATED_UTF8_CHAR The UTF-8 character may be valid but the given length is too small The Info node includes information about the master and is a required field. 400606 QERR_MISSING_ETHERCAT_MASTER_SOURCE Missing Source node within the Master section of an EtherCAT XML configuration file. To configure licensing use the Configure License utility found under Start Menu/All Programs/Quanser for your product. 400620 QERR_NO_QCC_FRAMEWORK_LICENSE You do not have a valid license for the Quanser Cooperative Control (QCC) navigate here It may be necessary to uncheck the two "Set PWM output parameters..." options in the HIL Initialize block. 400711 QERR_HIL_TASK_CREATE_ANALOG_READER_NOT_SUPPORTED The hil_task_create_analog_reader function and HIL Read Analog Timebase block are not

The Inputs node describes the EtherCAT input process image and is required. 400616 QERR_MISSING_ETHERCAT_PROCESS_INPUTS_SIZE Missing ByteSize node within the ProcessImage/Inputs section of the EtherCAT XML configuration file. Labview Error 50103 Open MAX andfind your device under Devices and Interfaces. which basically runs DAQmx Start Task if you didn't bother to.

It may be necessary to uncheck the two "Set analog output parameters..." options in the HIL Initialize block. 400702 QERR_HIL_SET_CARD_SPECIFIC_OPTIONS_NOT_SUPPORTED The hil_set_card_specific_options function is not supported by this particular card.

Make sure the wiimote is on and connected to the receiving device. 400646 QERR_WIIMOTE_CANNOT_OPEN Failed to open a connection to the wiimote. 400647 QERR_WIIMOTE_READ_FAILED A wiimote read request failed. 400648 QERR_WIIMOTE_NOT_FOUND I presume DAQmx Read is the VI throwing the error. Only one Timebase block may be present in the model. 400432 QERR_TIMEBASE_NOT_REGISTERED A Timebase block has not been registered. 400433 QERR_CANNOT_GET_PREFERENCES_VALUE The preferences value could not be retrieved. Labview Custom Error Codes If you are uploading a MAT file then the host and target are likely the same machine and the operation would overwrite the MAT file with itself. 400252 QERR_TOO_MANY_PROCESSES Too many

All rights reserved. Cart|Help KnowledgeBase Request Supportfrom an engineer NIHome > Support > KnowledgeBase English 13 rating: 1.53 out of 5   Where Can I The operation has been aborted. 400351 QERR_BUFFER_OVERFLOW For a read operation, the buffer has overflowed. A connection cannot be used after it has been closed. 400266 QERR_NON_BLOCKING_NOT_SUPPORTED Non-blocking mode is not supported for the given protocol. 400267 QERR_CANNOT_INITIALIZE_SOCKETS It was not possible to initialize the socket his comment is here Make sure both are up-to-date and compatible versions. 400356 QERR_INTERNAL_BUFFER_TOO_SMALL The board-specific HIL driver used an internal buffer that was too small for the operating system specific kernel-level driver for the

Try one of the more specific functions. 40072 ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.9/ Connection to 0.0.0.9 If you need access to this channel, use the generic version of this driver. 400673 QERR_MISSING_URI_OPTION_NAME No option name was found even though a value was specified. 400674 QERR_ENCODER_QUADRATURE_MODE_NOT_SUPPORTED The selected DAQmxGetErrorString will return a message that corresponds to the DAQmx error number, but the numbers you have are not DAQmx error codes. My Profile | RSS | Privacy | Legal | Contact NI © 2014 National Instruments Corporation.

If youget Error -88705, see the related links below to check the status of NI Device Loader. DAQmxGetErrorString doesnt work. Why would this cause an error? I made code to reset the device and make a DO signal again.

Channel numbers typically range from 0 to one less than the number of channels. 400365 QERR_DIGITAL_INPUT_CHANNELS_NOT_SUPPORTED Digital input channels are not supported by this board. 400366 QERR_TOO_MANY_DIGITAL_INPUT_CHANNELS Too many digital input You are still at the mercy of the shared timing subsystem. Escape ampersands using & to put ampersands in values. 400477 QERR_INVALID_XML_CHAR_REFERENCE The value of the character reference is not a valid character for XML. 400478 QERR_UNTERMINATED_XML_ATTRIBUTE_VALUE An XML attribute value string The State nodes identify the states in which the cyclic command should be sent and one is required. 400605 QERR_MISSING_ETHERCAT_MASTER_INFO Missing Info node within the Master section of an EtherCAT XML

My solution is to create a wrapper VI around DAQmx Read which implements a retry (in a While Loop) when error -50103 occurs, until the timeout expires. For example, you may be trying to run more than one model at a time when you are only licensed for one, or your license may have expired. Right-click your device and select Reset Device. Share this post Link to post Share on other sites Kevin P 1 Very Active Members 1 63 posts Posted August 15, 2007 I've rarely done software-timed data acq, but

A stream cannot be used after it has been closed. 400305 QERR_STREAM_BUFFER_TOO_SMALL The stream buffer is too small to send or receive units of the given size. 400306 QERR_INVALID_DPC The DPC Primary Software: Driver Software>>NI-DAQmx Primary Software Version: 8.6.1 Primary Software Fixed Version: N/A Secondary Software: LabWindows/CVI Run-Time Engine Problem: I need to do error checking in a programming environment other than I opened a support request with NI at the same time (2 hours ago) that I started this thread on LAVA. The Cmd node identifies the EtherCAT command and is a required field. 400592 QERR_MISSING_ETHERCAT_LOGICAL_ADDRESS Missing Addr node within an InitCmd in EtherCAT XML configuration file.

Ben Share this post Link to post Share on other sites jdunham 30 Extremely Active Members 30 625 posts Location:San Francisco, CA Version:LabVIEW 2011 Since:1994 Posted August 14, 2007 QUOTE(Jim You can turn this off, but the default is on. Is there any way I can keep them running in separate tasks and also get rid of that 50103 error?   FYI: I'm really new to the labview..    here is